4994D97G28
Circuit Breakers
CIRCUIT BREAKER
4994D97G28
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Trip Release Characteristic
instantaneous all locations
 - 
                                    
Pole Quantity
3
 - 
                                    
Circuit Protection Type
overcurrent all locations
 - 
                                    
Body Width
4.125 inches nominal
 - 
                                    
Reset Method
manual
 - 
                                    
Features Provided
adjustable trip release
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Actuator Function
trip-reset
 - 
                                    
Internal Trip Release Configuration
series trip all locations
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.500 inches nominal
 - 
                                    
Center To Center Distance Between Terminals Parallel To Width
1.375 inches nominal
 - 
                                    
Trip Release Method
magnetic all locations
 - 
                                    
Actuator Position Designation
at pole two
 - 
                                    
Adjustable Trip Setting Current Range Per Pole In Amps
+450.0/+825.0 ac all locations
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.375 inches nominal
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
5.062 inches nominal
 - 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
200.000 maximum at 200 pct all locations
 - 
                                    
Body Height
3.375 inches nominal
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac all locations
 - 
                                    
Case Material
plastic
 - 
                                    
Unthreaded Mounting Hole Diameter
0.187 inches nominal
 - 
                                    
Body Length
6.000 inches nominal
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
150.0 amperes ac all locations
 - 
                                    
Boss Height
0.125 inches nominal
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
 - 
                                    
Mounting Facility Type And Quantity
4 unthreaded hole
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Terminal Type And Quantity
6 compression
 - 
                                    
Frequency In Hertz
60.0 all locations
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
10000.0 ac all locations
 - 
                                    
Manual Actuator Type And Quantity
1 toggle
 - 
                                    
Body Style
multipole-single actuator type
 - 
                                    
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    