2XAM1516HKMG3-47-250VAC60C2
Circuit Breakers
CIRCUIT BREAKER
2XAM1516HKMG3-47-250VAC60C2
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Fragility Factor
moderately rugged
 - 
                                    
Switch Terminal Type
tab, solder lug
 - 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct all locations and 20.000 maximum at 200 pct all locations
 - 
                                    
Circuit Protection Type
overcurrent all locations
 - 
                                    
Pole Quantity
2
 - 
                                    
Thread Series Designator
unc
 - 
                                    
Actuator Position Designation
at each pole
 - 
                                    
Reset Method
manual
 - 
                                    
Mounting Surface To Terminal End Distance
3.239 inches nominal
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Switch Current Rating And Type In Amps
5.0 ac and 1.0 dc
 - 
                                    
Trip Release Characteristic
time delay all locations
 - 
                                    
Actuator Function
trip-reset
 - 
                                    
Internal Trip Release Configuration
series trip all locations
 - 
                                    
Switch Voltage Rating And Type In Volts
125.0 ac and 50.0 dc
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
3.053 inches minimum and 3.073 inches maximum
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
47.0 amperes ac all locations
 - 
                                    
Mounting Facility Type And Quantity
4 threaded hole
 - 
                                    
Thread Quantity Per Inch
32
 - 
                                    
Trip Release Method
magnetic-hydraulic all locations
 - 
                                    
Body Style
multipole-multiple actuator type
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
 - 
                                    
Switch Contact Arrangement
single pole, double throw
 - 
                                    
Body Width
2.021 inches minimum and 2.041 inches maximum
 - 
                                    
Nominal Thread Size
0.138 inches
 - 
                                    
Body Length
3.709 inches minimum and 3.729 inches maximum
 - 
                                    
Frequency In Hertz
60.0 all locations
 - 
                                    
Inclosure Protection Type For Which Designed
dustproof and fungus proof
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Arc Quenching Method
magnetic blowout
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.740 inches minimum and 2.760 inches maximum
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.021 inches minimum and 1.041 inches maximum
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1500.0 ac all locations
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
 - 
                                    
Manual Actuator Type And Quantity
2 toggle
 - 
                                    
Auxiliary Switch Function And Quantity
1 alarm
 - 
                                    
Boss Height
0.146 inches minimum and 0.166 inches maximum
 - 
                                    
Terminal Type And Quantity
4 threaded stud
 - 
                                    
Center To Center Distance Between Terminals Parallel To Width
1.021 inches minimum and 1.041 inches maximum
 - 
                                    
External Actuator Linkage Arrangement
one and two linked
 - 
                                    
Switch Location And Position Designation
internal at pole one
 - 
                                    
Case Material
plastic
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    