762-100
Switches
SWITCH,ROTARY
762-100
SWITCH,ROTARY
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Pole Quantity
1 each section rear
 - 
                                    
Switch Actuator Positioning Increment
45.0 degrees single actuator
 - 
                                    
Style Designator
tap, circuit selector
 - 
                                    
Contact Switching Action
breaks before makes each section rear
 - 
                                    
Shaft Length
0.750 inches nominal single actuator
 - 
                                    
Contact Load Current Rating
5.0 amperes resistive load dc at sea level
 - 
                                    
Longest Vertical Distance Between Mounting Centers
2.297 inches minimum single mounting facility and 2.299 inches maximum single mounting facility
 - 
                                    
Shaft Type
round, flatted single actuator
 - 
                                    
Contact Voltage Rating In Volts
125.0 ac at sea level
 - 
                                    
Mounting Facility Pattern
four position rectangular single mounting facility
 - 
                                    
Terminal Type
tab w/screw
 - 
                                    
Contact Voltage Rating In Volts
125.0 dc at sea level
 - 
                                    
Thread Series Designator
unf single mounting facility
 - 
                                    
Overall Width
2.813 inches nominal
 - 
                                    
Switch Contact Basic Design
nonpile-up symmetrical
 - 
                                    
Throw Quantity
3 each section rear
 - 
                                    
Contact Load Current Rating
10.0 amperes resistive load ac at sea level
 - 
                                    
Individual Section Quantity
10
 - 
                                    
Overall Height
2.813 inches nominal
 - 
                                    
Hazardous Locations/Environmental Protection
dustproof
 - 
                                    
Longest Horizontal Distance Between Mounting Centers
2.297 inches minimum single mounting facility and 2.299 inches maximum single mounting facility
 - 
                                    
Mounting Method
threaded hole single mounting facility
 - 
                                    
Flat Height
0.216 inches minimum single actuator and 0.218 inches maximum single actuator
 - 
                                    
Thread Class
2b single mounting facility
 - 
                                    
Switch Actuator Indexing Position Quantity
3 single actuator
 - 
                                    
Switch Actuator Stop Device Type
fixed stop single actuator
 - 
                                    
Nominal Thread Size
0.190 inches single mounting facility
 - 
                                    
Shaft Diameter
0.250 inches nominal single actuator
 - 
                                    
Overall Length
6.000 inches nominal
 - 
                                    
First Flat Length
0.750 inches nominal single actuator
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    