659001CB1

Circuit Breakers

CIRCUIT BREAKER

659001CB1

5925-00-024-0864

5925 - Circuit Breakers

Thermo Jarrell Ash Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Mounting Surface To Terminal End Distance

    2.461 inches minimum and 2.481 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.928 inches minimum and 1.948 inches maximum

  • Internal Trip Release Configuration

    relay trip third location

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Case Material

    plastic

  • Boss Height

    0.130 inches minimum and 0.150 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    3.5 amperes ac second location

  • Manual Actuator Type And Quantity

    3 toggle

  • Body Length

    2.490 inches minimum and 2.510 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    3.5 amperes ac first location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.300 minimum at 200 pct all locations and 1.000 maximum at 200 pct all locations

  • Maximum Continuous Load Current Rating Per Pole

    500.0 milliamperes ac third location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.052 inches minimum and 2.072 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Main Contact Tripping Mechanism Type

    trip free

  • Frequency In Hertz

    60.0 all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.740 inches minimum and 0.760 inches maximum

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip second location

  • Terminal Type And Quantity

    8 threaded stud

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Unpackaged Unit Weight

    14.000 ounces

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Body Width

    2.240 inches minimum and 2.260 inches maximum

  • Internal Trip Release Configuration

    series trip first location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Body Style

    multipole-multiple actuator type

  • Trip Release Method

    magnetic-hydraulic all locations

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...