20L10
Circuit Breakers
CIRCUIT BREAKER
20L10
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Trip Release Characteristictime delay single location 
- 
                                    Trip Release Ambient Temp Rating25.0 deg celsius nominal single location 
- 
                                    Body Width1.813 inches nominal 
- 
                                    Specification/Standard Data81349--13561/1 government specification 
- 
                                    Terminal Type And Quantity2 quick disconnect, male 
- 
                                    Body Stylesingle pole type 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent138.0 single location 
- 
                                    Reset Methodautomatic 
- 
                                    Case Materialplastic 
- 
                                    ~1data on certain environmental and performanc 
- 
                                    Fragility Factormoderately rugged 
- 
                                    Unthreaded Mounting Hole Diameter0.174 inches nominal 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Width1.566 inches minimum and 1.582 inches maximum 
- 
                                    Center To Center Distance Between Terminals Parallel To Length0.625 inches nominal 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts28.0 dc single location 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current8.000 minimum at 200 pct single location and 50.000 maximum at 200 pct single location 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Maximum Continuous Load Current Rating Per Pole15.0 amperes dc single location 
- 
                                    Body Length2.000 inches nominal 
- 
                                    Circuit Protection Typeovercurrent single location 
- 
                                    Trip Release Methodthermal single location 
- 
                                    Inclosure Protection Type For Which Designedwaterproof and vibration resistant and shock resistant and salt spray proof and fungus resistant 
- 
                                    Body Height1.875 inches maximum 
- 
                                    Pole Quantity1 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps575.0 dc single location 
- 
                                    Internal Trip Release Configurationseries trip single location 
- 
                                    Mounting Facility Type And Quantity2 unthreaded hole 
- 
                                    Test Data Document81349-mil-c-13516 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    