4913428-24
Circuit Breakers
CIRCUIT BREAKER
4913428-24
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps1000.0 ac single location and 1000.0 dc single location 
- 
                                    Nominal Thread Size0.375 inches 
- 
                                    Circuit Protection Typeovercurrent single location 
- 
                                    Trip Release Methodthermal single location 
- 
                                    Mounting Facility Type And Quantity1 threaded bushing 
- 
                                    Manual Actuator Type And Quantity1 push-pull 
- 
                                    Mounting Surface To Terminal End Distance2.260 inches nominal 
- 
                                    Pole Quantity1 
- 
                                    Internal Trip Release Configurationseries trip single location 
- 
                                    Trip Release Characteristictime delay single location 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 single location 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts250.0 ac single location and 24.0 dc single location 
- 
                                    Terminal Type And Quantity2 quick disconnect, male 
- 
                                    Body Stylesingle pole type 
- 
                                    Maximum Continuous Load Current Rating Per Pole10.0 amperes ac single location and 10.0 amperes dc single location 
- 
                                    Bushing Length0.390 inches nominal 
- 
                                    Frequency In Hertz60.0 single location 
- 
                                    Body Width0.570 inches nominal 
- 
                                    Thread Series Designatorun 
- 
                                    Body Length1.140 inches nominal 
- 
                                    Thread Quantity Per Inch28 
- 
                                    Case Materialplastic 
- 
                                    Actuator Functionreset 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current2.000 minimum at 400 pct single location and 9.000 maximum at 400 pct single location 
- 
                                    Center To Center Distance Between Terminals Parallel To Length0.890 inches nominal 
- 
                                    Trip Release Ambient Temp Rating70.0 deg fahrenheit nominal single location 
- 
                                    Reset Methodmanual 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    