CCPBA18
Circuit Breakers
CIRCUIT BREAKER
CCPBA18
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Fragility Factormoderately rugged 
- 
                                    Thread Series Designatorunc 
- 
                                    Reset Methodmanual 
- 
                                    Actuator Position Designationat pole one 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Manual Actuator Type And Quantity1 push button 
- 
                                    Terminal Type And Quantity2 screw 
- 
                                    Mounting Facility Type And Quantity2 threaded hole 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Circuit Protection Typeovercurrent single location 
- 
                                    Trip Release Ambient Temp Rating24.0 deg celsius nominal single location 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current23.000 minimum at 200 pct single location and 23.000 maximum at 300 pct single location 
- 
                                    Inclosure Protection Type For Which Designeddustproof and fungus resistant 
- 
                                    Switch Location And Position Designationinternal at pole one 
- 
                                    Auxiliary Switch Function And Quantity1 control 
- 
                                    Case Materialplastic 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts230.0 ac single location and 20.0 dc single location 
- 
                                    Trip Release Methodthermal single location 
- 
                                    Arc Quenching Methodair 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps200.0 ac single location and 200.0 dc single location 
- 
                                    Maximum Continuous Load Current Rating Per Pole8.0 amperes ac single location and 8.0 amperes dc single location 
- 
                                    Boss Height0.120 inches nominal 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent135.0 single location 
- 
                                    Switch Contact Arrangementsingle pole, double throw 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length1.000 inches nominal 
- 
                                    Switch Voltage Rating And Type In Volts115.0 ac and 50.0 dc 
- 
                                    Pole Quantity1 
- 
                                    Internal Trip Release Configurationseries trip single location 
- 
                                    Nominal Thread Size0.138 inches 
- 
                                    Trip Release Characteristictime delay single location 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Mounting Surface To Terminal End Distance1.910 inches nominal 
- 
                                    Overall Width0.997 inches maximum 
- 
                                    Body Stylesingle pole type 
- 
                                    Center To Center Distance Between Terminals Parallel To Length1.656 inches nominal 
- 
                                    Switch Terminal Typepin 
- 
                                    Frequency In Hertz60.0 single location 
- 
                                    Overall Length1.969 inches nominal 
- 
                                    Switch Current Rating And Type In Amps3.0 ac and 3.0 dc 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    