D5-19-5111
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
D5-19-5111
Edgewood Chemical Biological Center
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
3.750 inches nominal
 - 
                                    
Body Material
metal
 - 
                                    
Source Impedance Rating Per Function
50.0 ohms 5th radio interference
 - 
                                    
Functional Terminal Type And Quantity
1 connector, receptacle input 1st function
 - 
                                    
Unthreaded Mounting Hole Diameter
0.250 inches nominal
 - 
                                    
Functional Terminal Type And Quantity
1 threaded stud ground 3rd function
 - 
                                    
Load Impedance Per Function
50.0 ohms 3rd radio interference
 - 
                                    
Style Designator
rectangular terminal/terminals on opposite surfaces
 - 
                                    
Operating Voltage Rating And Type Per Function
120.0 volts ac 2nd radio interference 2nd function and 208.0 volts dc 2nd radio interference 2nd function
 - 
                                    
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
 - 
                                    
Body Width
3.000 inches nominal
 - 
                                    
Operating Voltage Rating And Type Per Function
50.0 volts dc 4th radio interference 4th function
 - 
                                    
Overall Length
8.750 inches nominal
 - 
                                    
Operating Temp Range
-25.0/+110.0 deg fahrenheit
 - 
                                    
Operating Voltage Rating And Type Per Function
120.0 volts ac 1st radio interference 1st function and 208.0 volts dc 1st radio interference 1st function
 - 
                                    
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference
 - 
                                    
Operating Current Rating Per Function In Amps
20.0 2nd radio interference
 - 
                                    
Load Impedance Per Function
50.0 ohms 1st radio interference
 - 
                                    
Operating Voltage Rating And Type Per Function
120.0 volts ac 3rd radio interference 3rd function and 208.0 volts dc 3rd radio interference 3rd function
 - 
                                    
Body Height
2.250 inches nominal
 - 
                                    
Power Line Frequency Rating Per Function In Hertz
60.0 3rd radio interference
 - 
                                    
Operating Current Rating Per Function In Amps
20.0 1st radio interference
 - 
                                    
Functional Terminal Type And Quantity
5 threaded stud output 2nd function
 - 
                                    
Load Impedance Per Function
50.0 ohms 5th radio interference
 - 
                                    
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
 - 
                                    
Power Line Frequency Rating Per Function In Hertz
60.0 2nd radio interference
 - 
                                    
Body Length
6.000 inches nominal
 - 
                                    
Operating Current Rating Per Function In Amps
4.0 5th radio interference
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
6.000 inches nominal
 - 
                                    
Operating Current Rating Per Function In Amps
4.0 4th radio interference
 - 
                                    
Power Line Frequency Rating Per Function In Hertz
60.0 1st radio interference
 - 
                                    
Mounting Facility Type And Quantity
4 unthreaded hole
 - 
                                    
Load Impedance Per Function
50.0 ohms 4th radio interference
 - 
                                    
Operating Voltage Rating And Type Per Function
50.0 volts dc 5th radio interference 5th function
 - 
                                    
Load Impedance Per Function
50.0 ohms 2nd radio interference
 - 
                                    
Operating Current Rating Per Function In Amps
20.0 3rd radio interference
 - 
                                    
Source Impedance Rating Per Function
50.0 ohms 4th radio interference
 - 
                                    
Maximum Dielectric Withstanding Dc Voltage
1.0 kilovolts at sea level and 200.0 volts at sea level
 - 
                                    
Inclosure Type
encased
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    