KS10404-28
Circuit Breakers
CIRCUIT BREAKER
KS10404-28
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Actuator Position Designation
at pole one
 - 
                                    
Internal Trip Release Configuration
series trip
 - 
                                    
Bushing Length
0.280 inches minimum and 0.380 inches maximum
 - 
                                    
Body Length
1.750 inches maximum
 - 
                                    
Case Material
metal
 - 
                                    
Mounting Surface To Terminal End Distance
1.700 inches maximum
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
750.0 milliamperes dc
 - 
                                    
Circuit Protection Type
overcurrent
 - 
                                    
Trip Release Method
magnetic
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
100.0
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
0.050 minimum at 200 pct and 0.950 maximum at 200 pct
 - 
                                    
Inclosure Protection Type For Which Designed
hermetically sealed
 - 
                                    
Test Data Document
84955-ks10404 drawing
 - 
                                    
Thread Series Designator
unef
 - 
                                    
Body Width
0.625 inches maximum
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
1.250 inches maximum
 - 
                                    
Pole Quantity
1
 - 
                                    
Mounting Facility Type And Quantity
1 threaded bushing
 - 
                                    
Thread Quantity Per Inch
32
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 dc
 - 
                                    
Trip Release Characteristic
time delay
 - 
                                    
Reset Method
manual
 - 
                                    
Manual Actuator Type And Quantity
1 toggle
 - 
                                    
Actuator Function
trip-reset
 - 
                                    
Nominal Thread Size
0.375 inches
 - 
                                    
Terminal Type And Quantity
2 wire hook
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    