Technical Characteristics
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Manual Actuator Type And Quantity1 push button 
- 
                                    Terminal Type And Quantity2 screw 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Circuit Protection Typeovercurrent single location 
- 
                                    Trip Release Methodthermal single location 
- 
                                    Pole Quantity1 
- 
                                    Maximum Continuous Load Current Rating Per Pole5.0 amperes ac single location and 5.0 amperes dc single location 
- 
                                    Mounting Surface To Terminal End Distance2.000 inches nominal 
- 
                                    Internal Trip Release Configurationseries trip single location 
- 
                                    Nominal Thread Size0.138 inches 
- 
                                    Body Width0.656 inches nominal 
- 
                                    Trip Release Characteristictime delay single location 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 single location 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Bushing Length0.234 inches nominal 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts30.0 ac single location and 30.0 dc single location 
- 
                                    Body Stylesingle pole type 
- 
                                    Mounting Facility Type And Quantity2 threaded bushing 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps100.0 ac single location and 100.0 dc single location 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length1.843 inches nominal 
- 
                                    Case Materialplastic 
- 
                                    Body Length2.187 inches nominal 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current6.600 nominal at 200 pct single location and 1.800 nominal at 300 pct single location 
- 
                                    Thread Series Designatorunc 
- 
                                    Reset Methodmanual 
- 
                                    Center To Center Distance Between Terminals Parallel To Length1.156 inches nominal 
- 
                                    Trip Release Ambient Temp Rating25.0 deg celsius maximum single location 
- 
                                    Actuator Position Designationat pole one 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    