90005
Switches
SWITCH,PRESSURE
90005
SWITCH,PRESSURE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Pressure Connector Type
plain, threaded internal single connection
 - 
                                    
Thread Quantity Per Inch
20 single pressure connection
 - 
                                    
Overall Height
1.500 inches nominal
 - 
                                    
Mounting Method
base
 - 
                                    
Contact Action Stimulus
increase
 - 
                                    
Sensing Element Burst Pressure
7500.00 pounds per square inch
 - 
                                    
Overall Width
1.500 inches nominal
 - 
                                    
Hazardous Locations/Environmental Protection
watertight
 - 
                                    
Body Length
4.000 inches nominal
 - 
                                    
Overall Length
4.110 inches maximum
 - 
                                    
Thread Class
3b single pressure connection
 - 
                                    
Thread Series Designator
unf single pressure connection
 - 
                                    
Style Designator
rectangular
 - 
                                    
Contact Load Current Rating
6.0 amperes resistive load single voltage
 - 
                                    
Media For Which Designed
gas or liquid
 - 
                                    
Inside Diameter
0.438 inches nominal single connection
 - 
                                    
Nonpile-Up Contact Arrangement
1 pole, double throw, one position momentary
 - 
                                    
Proof Pressure
4500.00 pounds per square inch
 - 
                                    
Distance Between Mounting Facility Centers
1.125 inches nominal
 - 
                                    
Nominal Thread Size
0.4375 inches single pressure connection
 - 
                                    
Pressure Switch Type
gage
 - 
                                    
Contact Adjustability
deactuation point not adjustable and actuation point not adjustable
 - 
                                    
Mounting Facility Pattern
two position in-line
 - 
                                    
Contact Stimulus Rating
2800.00 actuation point nominal pounds per square inch gage and 200.00 deactuation point nominal pounds per square inch gage
 - 
                                    
Err Default
err default
 - 
                                    
Terminal Type
connector, receptacle
 - 
                                    
Operating Temp Rating
-65.0 deg fahrenheit minimum and 160.0 deg fahrenheit maximum
 - 
                                    
Contact Voltage Rating In Volts
30.0 dc at sea level single voltage
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    