Technical Characteristics
- 
                                    
Test Data Document
81349-mil-c-55629 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
 - 
                                    
Fragility Factor
moderately rugged
 - 
                                    
Trip Release Method
magnetic single location
 - 
                                    
Special Handling Feature
magnetic
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
2.0 amperes dc single location
 - 
                                    
Thread Series Designator
unc
 - 
                                    
Reset Method
manual
 - 
                                    
Boss Height
0.150 inches nominal
 - 
                                    
Actuator Position Designation
at pole one
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Actuator Function
trip-reset
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
1.940 inches nominal
 - 
                                    
Mounting Facility Type And Quantity
2 threaded hole
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.050 inches minimum and 2.070 inches maximum
 - 
                                    
Thread Quantity Per Inch
32
 - 
                                    
Circuit Protection Type
overcurrent single location
 - 
                                    
Pole Quantity
1
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 dc single location
 - 
                                    
Manual Actuator Type And Quantity
1 toggle
 - 
                                    
Internal Trip Release Configuration
series trip single location
 - 
                                    
Nominal Thread Size
0.138 inches
 - 
                                    
Trip Release Characteristic
time delay single location
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Arc Quenching Method
magnetic blowout
 - 
                                    
Inclosure Protection Type For Which Designed
shock resistant and moisture resistant and vibration resistant
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc single location
 - 
                                    
Specification/Standard Data
81349-mil-c-55629/1 government specification
 - 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
0.150 minimum at 200 pct single location and 1.500 maximum at 200 pct single location
 - 
                                    
Body Style
single pole type
 - 
                                    
Mounting Surface To Terminal End Distance
2.475 inches nominal
 - 
                                    
Thread Pitch Diameters
+0.1177/+0.1214 inches
 - 
                                    
Body Length
2.480 inches minimum and 2.500 inches maximum
 - 
                                    
Body Width
0.750 inches maximum
 - 
                                    
Case Material
plastic
 - 
                                    
Terminal Type And Quantity
2 threaded stud
 - 
                                    
~1
data on certain environmental and performanc
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    