512-201-101

Circuit Breakers

CIRCUIT BREAKER

512-201-101

5925-00-170-4092

5925 - Circuit Breakers

Wood Electric Operations Potter And

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Pitch Diameters

    p0.1177/p0.1214 inches

  • Body Width

    1.515 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.530 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Fragility Factor

    moderately rugged

  • Boss Height

    0.130 inches nominal

  • Mounting Surface To Terminal End Distance

    2.000 inches maximum

  • Pole Quantity

    2

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3500.0 ac

  • Circuit Protection Type

    overcurrent

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip

  • Nominal Thread Size

    0.138 inches

  • Special Features

    actuator white with white markings

  • Frequency In Hertz

    50.0 or b60.0

  • Thread Series Designator

    unc

  • Body Length

    2.000 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.660 inches nominal

  • Arc Quenching Method

    magnetic blowout

  • Special Handling Feature

    magnetic

  • Maximum Continuous Load Current Rating Per Pole

    1.0 amperes ac

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac

  • Trip Release Method

    magnetic-hydraulic

  • Trip Release Characteristic

    time delay

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.130 minimum at 200 pct and 3.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    hermetically sealed and shock resistant and vibration resistant

  • Unpackaged Unit Weight

    4.400 ounces

  • Terminal Type And Quantity

    4 quick disconnect,male

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...