APG-11-1-61-102-09
Circuit Breakers
CIRCUIT BREAKER
APG-11-1-61-102-09
Sensata Technologies Maryland Inc
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Thread Pitch Diameters
p0.1177/p0.1214 inches
 - 
                                    
Body Width
1.515 inches maximum
 - 
                                    
Case Material
plastic
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
1.530 inches nominal
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
 - 
                                    
Fragility Factor
moderately rugged
 - 
                                    
Boss Height
0.130 inches nominal
 - 
                                    
Mounting Surface To Terminal End Distance
2.000 inches maximum
 - 
                                    
Pole Quantity
2
 - 
                                    
Mounting Facility Type And Quantity
4 threaded hole
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Thread Quantity Per Inch
32
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3500.0 ac
 - 
                                    
Circuit Protection Type
overcurrent
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Manual Actuator Type And Quantity
1 toggle
 - 
                                    
Internal Trip Release Configuration
series trip
 - 
                                    
Nominal Thread Size
0.138 inches
 - 
                                    
Special Features
actuator white with white markings
 - 
                                    
Frequency In Hertz
50.0 or b60.0
 - 
                                    
Thread Series Designator
unc
 - 
                                    
Body Length
2.000 inches nominal
 - 
                                    
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.660 inches nominal
 - 
                                    
Arc Quenching Method
magnetic blowout
 - 
                                    
Special Handling Feature
magnetic
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
1.0 amperes ac
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac
 - 
                                    
Trip Release Method
magnetic-hydraulic
 - 
                                    
Trip Release Characteristic
time delay
 - 
                                    
Reset Method
manual
 - 
                                    
Actuator Function
trip-reset
 - 
                                    
Actuator Position Designation
at pole one
 - 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
0.130 minimum at 200 pct and 3.000 maximum at 200 pct
 - 
                                    
Inclosure Protection Type For Which Designed
hermetically sealed and shock resistant and vibration resistant
 - 
                                    
Unpackaged Unit Weight
4.400 ounces
 - 
                                    
Terminal Type And Quantity
4 quick disconnect,male
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    