2667057-1
Coils and Transformers
TRANSFORMER,PULSE
2667057-1
TRANSFORMER,PULSE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Reliability Indicator
not established
-
Center To Center Distance Between Mounting Facilities Parallel To Length
8.969 inches minimum single mounting facility single center group and 9.031 inches maximum
-
Overall Width
8.560 inches maximum
-
Body Length
10.060 inches maximum
-
Body Height
8.560 inches maximum
-
Inclosure Type
hermetically sealed
-
Mounting Method
flange single group and unthreaded hole
-
Winding Function And Quantity
1 primary single component and 1 secondary
-
Winding Operating Current
300.0 amperes ac maximum single component single primary
-
Center To Center Distance Between Mounting Facilities Parallel To Width
7.469 inches minimum single mounting facility single center group and 7.531 inches maximum
-
Mounting Hole Diameter
0.427 inches minimum single group and 0.447 inches maximum
-
Pulse Duration In Microseconds
1.000 single component
-
Pulse Repetition Rate
400.0 hertz single component
-
Terminal Type And Quantity
2 standoff, threaded stud and 3 threaded stud
-
Peak Voltage Rating
12.0 kilovolts single component single secondary
-
Winding Operating Current
40.0 amperes ac minimum single component single secondary and 100.0 amperes ac maximum
-
Mounting Facility Quantity
4 single group
-
Winding Shielding Method
internal shield brought out to terminal single component
-
Test Data Document
10001-2667057 drawing
-
Peak Voltage Rating
2.0 kilovolts single component single primary