469400
Switches
SWITCH,THERMOSTATIC
469400
SWITCH,THERMOSTATIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Temp Sensing Element Type
capillary tube-bulb
 - 
                                    
Contact Adjustability
deactuation point adjustable and actuation point adjustable
 - 
                                    
Mounting Method
bracket and unthreaded hole
 - 
                                    
Contact Voltage Rating In Volts
230.0 ac at sea level first voltage
 - 
                                    
Media For Which Designed
liquid
 - 
                                    
Capillary Tube Length
16.4 inches nominal
 - 
                                    
Contact Load Current Rating
15.0 amperes resistive load first voltage
 - 
                                    
Contact Adjustment Type
external actuation point pointer and external actuation point knob and external deactuation point knob and external deactuation point pointer
 - 
                                    
Contact Adjustment Range
+105.00/+125.00 actuation point degrees fahrenheit and +105.00/+125.00 deactuation point degrees fahrenheit
 - 
                                    
Contact Load Current Rating
15.0 amperes resistive load second voltage
 - 
                                    
Overall Length
3.188 inches nominal
 - 
                                    
Overall Width
1.562 inches nominal
 - 
                                    
Unthreaded Mounting Hole Diameter
0.219 inches nominal
 - 
                                    
Style Designator
rectangular
 - 
                                    
Bulb Length
4.188 inches nominal
 - 
                                    
Nonpile-Up Contact Arrangement
1 pole, single throw, normally closed, momentary action
 - 
                                    
Contact Voltage Rating In Volts
115.0 ac at sea level second voltage
 - 
                                    
Features Provided
electrical access port
 - 
                                    
Body Height
2.750 inches nominal
 - 
                                    
Distance Between Mounting Facility Centers
2.250 inches nominal
 - 
                                    
Terminal Type
wire lead
 - 
                                    
Mounting Facility Pattern
two position in-line
 - 
                                    
Overall Height
6.938 inches nominal
 - 
                                    
Contact Action Stimulus
increase
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    