112-250-101

Circuit Breakers

CIRCUIT BREAKER

112-250-101

5925-00-199-9565

5925 - Circuit Breakers

Wood Electric Operations Potter And

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac single location and 50.0 amperes dc single location

  • Inclosure Protection Type For Which Designed

    salt spray proof and humidity proof and shockproof and vibrationproof

  • Reset Method

    manual

  • Trip Delay Time In Seconds Per Rated Continuous Current

    6.000 minimum at 200 pct single location and 22.000 maximum at 200 pct single location

  • Actuator Position Designation

    at pole one

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location and 1000.0 dc single location

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Arc Quenching Method

    air

  • Thread Series Designator

    uns

  • Center To Center Distance Between Terminals Parallel To Length

    1.020 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location and 50.0 dc single location

  • Nominal Thread Size

    0.469 inches

  • Unpackaged Unit Weight

    0.125 pounds

  • Terminal Type And Quantity

    2 tab w/screw

  • Body Style

    single pole type

  • Frequency In Hertz

    400.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Trip Release Characteristic

    time delay single location

  • Bushing Length

    0.335 inches nominal

  • Body Width

    0.690 inches nominal

  • Internal Trip Release Configuration

    series trip single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Pole Quantity

    1

  • Mounting Surface To Terminal End Distance

    2.035 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0 single location

  • Body Length

    1.375 inches nominal

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...