1090142

Circuit Breakers

CIRCUIT BREAKER

1090142

5925-00-201-4793

5925 - Circuit Breakers

Chief Of Engineers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.349 inches minimum and 4.369 inches maximum

  • Reset Method

    manual

  • Boss Height

    0.208 inches minimum and 0.228 inches maximum

  • Storage Type

    general purpose warehouse

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 dc all locations

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Maximum Continuous Load Current Rating Per Pole

    25.0 amperes dc all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.990 inches minimum and 1.010 inches maximum

  • Body Width

    2.990 inches minimum and 3.010 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    125.0 dc all locations

  • Center To Center Distance Between Terminals Parallel To Length

    4.349 inches minimum and 4.369 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Main Contact Tripping Mechanism Type

    trip free

  • Inclosure Protection Type For Which Designed

    dustproof and fungus proof

  • Center To Center Distance Between Terminals Parallel To Width

    0.990 inches minimum and 1.010 inches maximum

  • Manual Actuator Type And Quantity

    1 toggle

  • Body Style

    multipole-single actuator type

  • Trip Delay Time In Seconds Per Rated Continuous Current

    3.000 minimum at 200 pct all locations and 10.000 maximum at 200 pct all locations

  • Mounting Surface To Terminal End Distance

    3.302 inches minimum and 3.322 inches maximum

  • Actuator Position Designation

    at pole two

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Terminal Type And Quantity

    6 threaded stud

  • Case Material

    plastic

  • Unthreaded Mounting Hole Diameter

    0.190 inches nominal

  • Body Length

    5.240 inches minimum and 5.260 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...