7270-7-10
Circuit Breakers
CIRCUIT BREAKER
7270-7-10
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Bushing Length
0.250 inches nominal
 - 
                                    
Pole Quantity
1
 - 
                                    
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac and 10.0 amperes dc
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac and 30.0 dc
 - 
                                    
Trip Release Characteristic
time delay
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0
 - 
                                    
Reset Method
manual
 - 
                                    
Actuator Function
trip-reset
 - 
                                    
Actuator Position Designation
at pole one
 - 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
20.000 minimum at 200 pct and 70.000 maximum at 200 pct
 - 
                                    
Inclosure Protection Type For Which Designed
corrosion resistant and explosion resistant and fungus proof
 - 
                                    
Frequency In Hertz
400.0
 - 
                                    
Terminal Type And Quantity
2 tab w/screw
 - 
                                    
Body Length
1.375 inches maximum
 - 
                                    
Body Width
0.750 inches maximum
 - 
                                    
Case Material
plastic
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
0.906 inches nominal
 - 
                                    
Mounting Surface To Terminal End Distance
1.312 inches nominal
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Thread Quantity Per Inch
32
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3500.0 ac and 4000.0 dc
 - 
                                    
Circuit Protection Type
overcurrent
 - 
                                    
Trip Release Method
thermal
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Manual Actuator Type And Quantity
1 toggle
 - 
                                    
Internal Trip Release Configuration
series trip
 - 
                                    
Nominal Thread Size
0.469 inches
 - 
                                    
Trip Release Ambient Temp Rating
25.0 deg celsius nominal
 - 
                                    
Unpackaged Unit Weight
1.500 ounces
 - 
                                    
Thread Series Designator
uns
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    