G330028S2
Circuit Breakers
CIRCUIT BREAKER
G330028S2
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    External Actuator Linkage Arrangementone, two, and three linked 
- 
                                    Internal Trip Release Configurationseries trip all locations 
- 
                                    Nominal Thread Size0.138 inches 
- 
                                    Unpackaged Unit Weight1.770 pounds 
- 
                                    Thread Series Designatorunc 
- 
                                    Terminal Type And Quantity6 threaded stud 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts250.0 ac all locations 
- 
                                    Circuit Protection Typeovercurrent all locations 
- 
                                    Trip Release Characteristictime delay all locations 
- 
                                    Reset Methodmanual 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Manual Actuator Type And Quantity3 toggle 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Actuator Position Designationat each pole 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current0.600 minimum at 200 pct and 3.000 maximum at 200 pct all locations 
- 
                                    Inclosure Protection Type For Which Designedfungus resistant and vibration resistant and shock resistant 
- 
                                    Frequency In Hertz400.0 
- 
                                    Body Style8c multipole-multiple actuator type 
- 
                                    Case Materialplastic 
- 
                                    Center To Center Distance Between Terminals Parallel To Width1.025 inches minimum and 1.035 inches maximum 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length2.740 inches minimum and 2.760 inches maximum 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Width1.025 inches minimum and 1.035 inches maximum 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Special Handling Featuremagnetic 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps1500.0 ac all locations 
- 
                                    Trip Release Methodmagnetic-hydraulic all locations 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent150.0 
- 
                                    Body Length3.725 inches minimum and 3.735 inches maximum 
- 
                                    Body Width3.055 inches minimum and 3.065 inches maximum 
- 
                                    Center To Center Distance Between Terminals Parallel To Length3.040 inches minimum and 3.060 inches maximum 
- 
                                    Fragility Factormoderately rugged 
- 
                                    Boss Height0.155 inches minimum and 0.165 inches maximum 
- 
                                    Mounting Surface To Terminal End Distance3.305 inches minimum and 3.435 inches maximum 
- 
                                    Pole Quantity3 
- 
                                    Mounting Facility Type And Quantity6 threaded hole 
- 
                                    Maximum Continuous Load Current Rating Per Pole70.0 amperes ac all locations 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    