AM1-Z22-017
Circuit Breakers
CIRCUIT BREAKER
AM1-Z22-017
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Terminal Type And Quantity2 threaded stud 
- 
                                    Case Materialplastic 
- 
                                    Body Width0.750 inches maximum 
- 
                                    Body Length2.480 inches minimum and 2.500 inches maximum 
- 
                                    Thread Pitch Diameters+0.1177/+0.1214 inches 
- 
                                    Frequency In Hertz60.0 single location 
- 
                                    Mounting Surface To Terminal End Distance2.475 inches nominal 
- 
                                    Body Stylesingle pole type 
- 
                                    Specification/Standard Data81349-mil-c-55629/1 government specification 
- 
                                    Maximum Continuous Load Current Rating Per Pole1.0 amperes ac single location 
- 
                                    Inclosure Protection Type For Which Designedmoisture resistant and shock resistant and vibration resistant 
- 
                                    Arc Quenching Methodmagnetic blowout 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 single location 
- 
                                    Trip Release Characteristictime delay single location 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps5000.0 ac single location 
- 
                                    Test Data Document81349-mil-c-55629 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type 
- 
                                    ~1data on certain environmental and performanc 
- 
                                    Nominal Thread Size0.138 inches 
- 
                                    Internal Trip Release Configurationseries trip single location 
- 
                                    Manual Actuator Type And Quantity1 toggle 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current2.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location 
- 
                                    Pole Quantity1 
- 
                                    Circuit Protection Typeovercurrent single location 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length2.050 inches minimum and 2.070 inches maximum 
- 
                                    Mounting Facility Type And Quantity2 threaded hole 
- 
                                    Center To Center Distance Between Terminals Parallel To Length1.940 inches nominal 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Actuator Position Designationat pole one 
- 
                                    Boss Height0.150 inches nominal 
- 
                                    Reset Methodmanual 
- 
                                    Thread Series Designatorunc 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts240.0 ac single location 
- 
                                    Special Handling Featuremagnetic 
- 
                                    Trip Release Methodmagnetic single location 
- 
                                    Fragility Factormoderately rugged 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    