Technical Characteristics
- 
                                    
Internal Trip Release Configuration
series trip single location
 - 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
20.000 minimum at 200 pct single location and 150.000 maximum at 200 pct single location
 - 
                                    
Mounting Facility Type And Quantity
2 unthreaded hole
 - 
                                    
Trip Release Characteristic
time delay single location
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Trip Release Ambient Temp Rating
77.0 deg fahrenheit nominal single location
 - 
                                    
Frequency In Hertz
400.0 single location
 - 
                                    
Body Style
single pole type
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac single location and 30.0 dc single location
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
 - 
                                    
Unthreaded Mounting Hole Diameter
0.190 inches nominal
 - 
                                    
Actuator Function
reset
 - 
                                    
Fragility Factor
moderately rugged
 - 
                                    
Reset Method
manual
 - 
                                    
Actuator Position Designation
at pole one
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Body Width
1.250 inches nominal
 - 
                                    
Manual Actuator Type And Quantity
1 push button
 - 
                                    
Terminal Type And Quantity
2 screw
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
0.453 inches nominal
 - 
                                    
Inclosure Protection Type For Which Designed
shockproof
 - 
                                    
Circuit Protection Type
overcurrent single location
 - 
                                    
Trip Release Method
thermal single location
 - 
                                    
Arc Quenching Method
air
 - 
                                    
Mounting Surface To Terminal End Distance
1.266 inches nominal
 - 
                                    
Unpackaged Unit Weight
5.000 ounces
 - 
                                    
Pole Quantity
1
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.574 inches nominal
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
875.0 ac single location and 875.0 dc single location
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
80.0 amperes ac single location and 80.0 amperes dc single location
 - 
                                    