APL1-55629-1-130
Circuit Breakers
CIRCUIT BREAKER
APL1-55629-1-130
Sensata Technologies Maryland Inc
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Pole Quantity
1
-
Manual Actuator Type And Quantity
1 toggle
-
Internal Trip Release Configuration
series trip single location
-
Nominal Thread Size
0.138 inches
-
Trip Release Characteristic
time delay single location
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Inclosure Protection Type For Which Designed
shock resistant and moisture resistant and vibration resistant
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 single location
-
Specification/Standard Data
81349-mil-c-55629/1 government specification
-
Body Style
single pole type
-
Mounting Surface To Terminal End Distance
2.475 inches nominal
-
Thread Quantity Per Inch
32
-
Circuit Protection Type
overcurrent single location
-
Test Data Document
81349-mil-c-55629 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.050 inches minimum and 2.070 inches maximum
-
Frequency In Hertz
60.0 single location
-
Thread Pitch Diameters
+0.1177/+0.1214 inches
-
Body Length
2.480 inches minimum and 2.500 inches maximum
-
Body Width
0.750 inches maximum
-
Case Material
plastic
-
Terminal Type And Quantity
2 threaded stud
-
~1
data on certain environmental and performanc
-
Fragility Factor
moderately rugged
-
Trip Release Method
magnetic single location
-
Maximum Continuous Load Current Rating Per Pole
50.0 amperes ac single location
-
Special Handling Feature
magnetic
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac single location
-
Thread Series Designator
unc
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location
-
Reset Method
manual
-
Boss Height
0.150 inches nominal
-
Actuator Position Designation
at pole one
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Center To Center Distance Between Terminals Parallel To Length
1.940 inches nominal
-
Mounting Facility Type And Quantity
2 threaded hole
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.130 minimum at 200 pct single location and 1.600 maximum at 200 pct single location
Related Parts by Category
Related Parts by Manufacturer


AS6081 Methods