050-004530
Coils and Transformers
TRANSFORMER,POWER
050-004530
Northrop Grumman Systems Corporation
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Facility Quantity
4 single group
-
Frequency Rating
380.0 hertz minimum single component and 420.0 hertz maximum single component
-
Winding Shielding Method
internal shield grounded to inclosure and core single component
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.625 inches nominal single mounting facility single center group
-
Winding Operating Current
300.0 milliamperes ac maximum single component 2nd secondary
-
Mounting Method
flange single group and unthreaded hole single group
-
Winding Operating Voltage
46.00 ac volts nominal single component 2nd secondary
-
Winding Function And Quantity
1 primary single component and 2 secondary single component
-
Inclosure Type
fully inclosed
-
Terminal Type And Quantity
7 tab, solder lug
-
Maximum Operating Temp
105.0 deg celsius
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.125 inches nominal single mounting facility single center group
-
Reliability Indicator
not established
-
Winding Operating Current
1.0 amperes ac maximum single component 1st secondary
-
Body Length
2.055 inches minimum and 2.065 inches maximum
-
Input-Output Phase Relationship
single phase to single phase single component
-
Winding Operating Voltage
115.00 ac volts nominal single component single primary
-
Mounting Hole Diameter
0.154 inches nominal single group
-
Body Width
1.495 inches minimum and 1.505 inches maximum
-
Body Height
1.745 inches minimum and 1.755 inches maximum
-
Winding Operating Voltage
12.00 ac volts nominal single component 1st secondary
Related Parts by Category
Related Parts by Manufacturer


AS6081 Methods