APL11-55629-3-082
Circuit Breakers
CIRCUIT BREAKER
APL11-55629-3-082
Sensata Technologies Maryland Inc
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Internal Trip Release Configurationseries trip all locations 
- 
                                    Definitive Government Spec/Std Referencem55629/3-082 
- 
                                    Thread Series Designatorunc 
- 
                                    Center To Center Distance Between Terminals Parallel To Width0.719 inches minimum and 0.781 inches maximum 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length2.046 inches minimum and 2.078 inches maximum 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Width0.719 inches minimum and 0.781 inches maximum 
- 
                                    Mounting Surface To Terminal End Distance2.553 inches maximum 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts240.0 ac all locations 
- 
                                    Reset Methodmanual 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Actuator Position Designationat each pole 
- 
                                    Nominal Thread Size0.138 inches 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current2.100 minimum at 200 pct and 20.000 maximum at 200 pct all locations 
- 
                                    Inclosure Protection Type For Which Designedshock resistant and vibration resistant 
- 
                                    Frequency In Hertz400.0 all locations 
- 
                                    Manufacturers Code81349 
- 
                                    Non-Definitive Government Spec/Std Referencemil-c-55629/3 
- 
                                    Test Data Document81349-mil-c-55629 specification 
- 
                                    Terminal Type And Quantity4 threaded stud 
- 
                                    Specification/Standard Data81349-mil-c-55629/3 government specification 
- 
                                    Thread Pitch Diameters0.1177 to 0.1214 inches 
- 
                                    Body Style8c multipole-multiple actuator type 
- 
                                    Body Length2.510 inches maximum 
- 
                                    Body Width1.437 inches minimum and 1.563 inches maximum 
- 
                                    Case Materialplastic 
- 
                                    Center To Center Distance Between Terminals Parallel To Length1.660 inches minimum and 1.960 inches maximum 
- 
                                    Iii Fragility Factormoderately rugged 
- 
                                    Boss Height0.109 inches minimum and 0.171 inches maximum 
- 
                                    Pole Quantity2 
- 
                                    Iii Arc Quenching Methodmagnetic blowout 
- 
                                    Mounting Facility Type And Quantity4 threaded hole 
- 
                                    Iii Storage Typegeneral purpose warehouse 
- 
                                    Maximum Continuous Load Current Rating Per Pole10.0 amperes ac all locations 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps1000.0 ac all locations 
- 
                                    Circuit Protection Typeovercurrent all locations 
- 
                                    Trip Release Methodmagnetic all locations 
- 
                                    Trip Release Characteristictime delay all locations 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent115.0 all locations 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Manual Actuator Type And Quantity2 toggle 
- 
                                    External Actuator Linkage Arrangementone and two linked 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    