7703949
Circuit Breakers
CIRCUIT BREAKER
7703949
Army United States Department Of The
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Operating Voltage Type And Rating Per Pole In Volts110.0 ac single location and 30.0 dc single location 
- 
                                    Internal Trip Release Configurationseries trip single location 
- 
                                    Mounting Facility Type And Quantity2 unthreaded hole 
- 
                                    Trip Release Characteristictime delay single location 
- 
                                    Trip Release Ambient Temp Rating25.0 deg celsius nominal single location 
- 
                                    Frequency In Hertz400.0 single location 
- 
                                    Body Stylesingle pole type 
- 
                                    Maximum Continuous Load Current Rating Per Pole10.0 amperes ac single location and 10.0 amperes dc single location 
- 
                                    Center To Center Distance Between Terminals Parallel To Length0.906 inches nominal 
- 
                                    Overall Length2.000 inches nominal 
- 
                                    Reset Methodautomatic 
- 
                                    Case Materialplastic 
- 
                                    Circuit Protection Typeovercurrent single location 
- 
                                    Trip Release Methodthermal single location 
- 
                                    Mounting Surface To Terminal End Distance1.266 inches nominal 
- 
                                    Unthreaded Mounting Hole Diameter0.250 inches nominal 
- 
                                    Inclosure Protection Type For Which Designedfungus resistant 
- 
                                    Pole Quantity1 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length1.574 inches nominal 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent130.0 single location 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps900.0 ac single location and 900.0 dc single location 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Body Width1.250 inches nominal 
- 
                                    Unpackaged Unit Weight1.500 ounces 
- 
                                    Terminal Type And Quantity2 screw 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current6.000 minimum at 200 pct single location and 50.000 maximum at 200 pct single location 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    