3263-5-A-250-1-60
Circuit Breakers
CIRCUIT BREAKER
3263-5-A-250-1-60
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Body Height2.677 inches minimum and 
- 
                                    Body Height2.697 inches maximum 
- 
                                    Case Materialplastic 
- 
                                    Center To Center Distance Between Terminals Parallel To Length4.369 inches maximum 
- 
                                    Center To Center Distance Between Terminals Parallel To Width0.994 inches maximum 
- 
                                    Unthreaded Mounting Hole Diameter0.190 inches nominal 
- 
                                    Switch Contact Arrangementsingle pole, double throw 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Width0.974 inches minimum and 
- 
                                    Iii Fragility Factormoderately rugged 
- 
                                    Pole Quantity3 
- 
                                    Mounting Facility Type And Quantity4 threaded hole and 
- 
                                    Mounting Facility Type And Quantity4 unthreaded hole 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts250.0 ac first location 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps5000.0 ac first location 
- 
                                    Circuit Protection Typeovercurrent first location 
- 
                                    Circuit Protection Typeovercurrent second location 
- 
                                    Trip Release Methodmagnetic-hydraulic first location 
- 
                                    Trip Release Characteristictime delay first location 
- 
                                    Trip Release Characteristictime delay second location 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 first location 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 second location 
- 
                                    Manual Actuator Type And Quantity1 toggle 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Actuator Position Designationat pole two 
- 
                                    Internal Trip Release Configurationseries trip first location 
- 
                                    Nominal Thread Size0.164 inches 
- 
                                    Switch Location And Position Designationexternal at pole three 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current120.000 maximum at 200 pct first location 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current38.000 minimum at 200 pct and 
- 
                                    Inclosure Protection Type For Which Designeddustproof and 
- 
                                    Inclosure Protection Type For Which Designedfungus proof 
- 
                                    Switch Terminal Typethreaded stud 
- 
                                    Special Featurespole three is a switch only 
- 
                                    Frequency In Hertz60.0 all locations 
- 
                                    Thread Series Designatorunc 
- 
                                    Body Style11b multipole-single actuator type 
- 
                                    Body Length5.240 inches minimum and 
- 
                                    Body Length65.260 inches maximum 
- 
                                    Body Width2.990 inches minimum and 
- 
                                    Body Width3.010 inches maximum 
- 
                                    Center To Center Distance Between Terminals Parallel To Length4.349 inches minimum and 
- 
                                    Center To Center Distance Between Terminals Parallel To Width0.974 inches minimum and 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length3.052 inches minimum and 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length3.072 inches maximum 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Width0.994 inches maximum 
- 
                                    Boss Height0.208 inches minimum and 
- 
                                    Boss Height0.228 inches maximum 
- 
                                    Iii Arc Quenching Methodmagnetic blowout 
- 
                                    Iii Storage Typegeneral purpose warehouse 
- 
                                    Maximum Continuous Load Current Rating Per Pole5.0 amperes ac first location 
- 
                                    Maximum Continuous Load Current Rating Per Pole5.0 amperes ac second location 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts250.0 ac second location 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps5000.0 ac second location 
- 
                                    Trip Release Methodmagnetic-hydraulic second location 
- 
                                    Reset Methodmanual 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Auxiliary Switch Function And Quantity1 control 
- 
                                    Internal Trip Release Configurationseries trip second location 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current120.000 maximum at 200 pct second location 
- 
                                    Terminal Type And Quantity4 threaded stud 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    