SU1000
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
SU1000
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Maximum Voltage Drop Per Function
1.2 volts ac 1st radio interference
 - 
                                    
Operating Temp Range
-28.0/+75.0 deg celsius
 - 
                                    
Body Surface Treatment
tin
 - 
                                    
Functional Terminal Type And Quantity
2 tab w/screw input 1st function
 - 
                                    
Source Impedance Rating Per Function
20.0 ohms 1st radio interference
 - 
                                    
Operating Voltage Rating And Type Per Function
115.0 volts ac 1st radio interference 1st function
 - 
                                    
Body Material
metal
 - 
                                    
Principal Circuitry Type Per Function
inductance-capacitance 2nd radio interference
 - 
                                    
Functional Terminal Type And Quantity
2 tab w/screw output 2nd function
 - 
                                    
Source Impedance Rating Per Function
20.0 ohms 2nd radio interference
 - 
                                    
Maximum Voltage Drop Per Function
1.2 volts ac 2nd radio interference
 - 
                                    
Style Designator
rectangular terminal/terminals on opposite surfaces
 - 
                                    
Load Impedance Per Function
20.0 ohms 2nd radio interference
 - 
                                    
Overall Length
5.625 inches maximum
 - 
                                    
Principal Circuitry Type Per Function
inductance-capacitance 1st radio interference
 - 
                                    
Operating Current Rating Per Function In Amps
20.0 2nd radio interference
 - 
                                    
Load Impedance Per Function
20.0 ohms 1st radio interference
 - 
                                    
Mounting Facility Type And Quantity
4 terminal
 - 
                                    
Inclosure Type
hermetically sealed
 - 
                                    
Overall Height
1.344 inches nominal
 - 
                                    
Operating Current Rating Per Function In Amps
20.0 1st radio interference
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.375 inches nominal
 - 
                                    
Power Line Frequency Rating Per Function In Hertz
60.0 2nd radio interference
 - 
                                    
Power Line Frequency Rating Per Function In Hertz
60.0 1st radio interference
 - 
                                    
Body Length
4.156 inches nominal
 - 
                                    
Operating Voltage Rating And Type Per Function
115.0 volts ac 2nd radio interference 2nd function
 - 
                                    
Body Width
3.000 inches nominal
 - 
                                    
Maximum Dielectric Withstanding Dc Voltage
500.0 volts at sea level
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    