M39019-5-11
Circuit Breakers
CIRCUIT BREAKER
M39019-5-11
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Body Style1b multipole-single actuator type 
- 
                                    Bushing Length0.380 inches maximum 
- 
                                    Center To Center Distance Between Terminals Parallel To Width1.250 inches nominal 
- 
                                    Mounting Surface To Terminal End Distance1.828 inches maximum 
- 
                                    Pole Quantity3 
- 
                                    Mounting Facility Type And Quantity1 threaded bushing 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Trip Release Methodmagnetic all locations 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 all locations 
- 
                                    Ultimate Trip Time Per Pole In Seconds0.200 minimum all locations and 7.000 maximum 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Body Length1.562 inches maximum 
- 
                                    Body Width1.937 inches maximum 
- 
                                    Case Materialmetal 
- 
                                    Center To Center Distance Between Terminals Parallel To Length0.906 inches maximum 
- 
                                    Maximum Continuous Load Current Rating Per Pole500.0 milliamperes dc all locations 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts50.0 dc all locations 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps500.0 dc all locations 
- 
                                    Circuit Protection Typeovercurrent all locations 
- 
                                    Trip Release Characteristictime delay all locations 
- 
                                    Reset Methodmanual 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Manual Actuator Type And Quantity1 toggle 
- 
                                    Actuator Position Designationat pole two 
- 
                                    Internal Trip Release Configurationseries trip all locations 
- 
                                    Nominal Thread Size0.375 inches 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current0.055 minimum at 200 pct all locations and 0.950 maximum at 200 pct and 0.240 maximum at 400 pct 
- 
                                    Inclosure Protection Type For Which Designedfungus resistant and hermetically sealed 
- 
                                    Test Data Document81349-mil-c-39019 specification 
- 
                                    Thread Series Designatorunef 
- 
                                    Terminal Type And Quantity6 wire hook 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    