JA1A3152502A
Circuit Breakers
CIRCUIT BREAKER
JA1A3152502A
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Center To Center Distance Between Terminals Parallel To Length1.555 inches minimum and 1.565 inches maximum 
- 
                                    Pole Quantity1 
- 
                                    Arc Quenching Methodair 
- 
                                    Mounting Facility Type And Quantity2 threaded hole 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Maximum Continuous Load Current Rating Per Pole15.0 amperes ac 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts250.0 ac 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps1000.0 ac 
- 
                                    Circuit Protection Typeovercurrent 
- 
                                    Trip Release Methodmagnetic-hydraulic 
- 
                                    Trip Release Characteristictime delay 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent135.0 
- 
                                    Reset Methodmanual 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Nominal Thread Size0.138 inches 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current2.000 minimum at 200 pct and 20.000 maximum at 200 pct 
- 
                                    Thread Series Designatorunc 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length1.655 inches minimum and 1.665 inches maximum 
- 
                                    Fragility Factormoderately rugged 
- 
                                    Boss Height0.125 inches minimum and 0.135 inches maximum 
- 
                                    Mounting Surface To Terminal End Distance1.875 inches minimum and 1.885 inches maximum 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Manual Actuator Type And Quantity1 toggle 
- 
                                    Internal Trip Release Configurationseries trip 
- 
                                    Inclosure Protection Type For Which Designeddustproof 
- 
                                    Frequency In Hertz60.0 
- 
                                    Terminal Type And Quantity2 tab,solder lug 
- 
                                    Body Width0.745 inches minimum and 0.755 inches maximum 
- 
                                    Body Length1.985 inches minimum and 2.015 inches maximum 
- 
                                    Case Materialplastic 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    