11207114-35
Circuit Breakers
CIRCUIT BREAKER
11207114-35
Ballistic Missile Defense Systems
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Ultimate Trip Time Per Pole In Seconds60.000 maximum all locations 
- 
                                    Reset Methodmanual 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Actuator Position Designationat each pole 
- 
                                    Internal Trip Release Configurationrelay trip fourth location 
- 
                                    Internal Trip Release Configurationseries trip second location 
- 
                                    Internal Trip Release Configurationseries trip third location 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current12.000 nominal at 150 pct first location 
- 
                                    Switch Terminal Typeturret 
- 
                                    Switch Voltage Rating And Type In Volts250.0 ac and 50.0 dc 
- 
                                    Test Data Document17773-11207114 drawing 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts50.0 dc fourth location 
- 
                                    Case Materialplastic 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Width0.740 inches minimum and 0.760 inches maximum 
- 
                                    Mounting Facility Type And Quantity8 threaded hole 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Maximum Continuous Load Current Rating Per Pole30.0 amperes dc fourth location 
- 
                                    Maximum Continuous Load Current Rating Per Pole5.0 amperes ac first location 
- 
                                    Maximum Continuous Load Current Rating Per Pole5.0 amperes ac second location 
- 
                                    Maximum Continuous Load Current Rating Per Pole5.0 amperes ac third location 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts250.0 ac first location 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts250.0 ac second location 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts250.0 ac third location 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps1000.0 ac third location 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps2000.0 dc fourth location 
- 
                                    Trip Release Methodmagnetic all locations 
- 
                                    Trip Release Characteristicinstantaneous and time delay all locations 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Manual Actuator Type And Quantity4 toggle 
- 
                                    External Actuator Linkage Arrangementone, two, three, and four linked 
- 
                                    Auxiliary Switch Function And Quantity3 control 
- 
                                    Internal Trip Release Configurationseries trip first location 
- 
                                    Nominal Thread Size0.138 inches 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current0.900 nominal at 150 pct fourth location 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current12.000 nominal at 150 pct second location 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current12.000 nominal at 150 pct third location 
- 
                                    Switch Current Rating And Type In Amps2.5 ac and 1.0 dc 
- 
                                    Frequency In Hertz60.0 
- 
                                    Thread Series Designatorunc 
- 
                                    Terminal Type And Quantity10 threaded stud 
- 
                                    Body Style8c multipole-multiple actuator type 
- 
                                    Body Length2.490 inches minimum and 2.510 inches maximum 
- 
                                    Body Width2.990 inches minimum and 3.010 inches maximum 
- 
                                    Center To Center Distance Between Terminals Parallel To Length1.928 inches minimum and 1.948 inches maximum 
- 
                                    Center To Center Distance Between Terminals Parallel To Width0.740 inches minimum and 0.760 inches maximum 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length2.052 inches minimum and 2.072 inches maximum 
- 
                                    Switch Contact Arrangementsingle pole, double throw 
- 
                                    Boss Height0.130 inches minimum and 0.150 inches maximum 
- 
                                    Mounting Surface To Terminal End Distance3.001 inches minimum and 3.125 inches maximum 
- 
                                    Pole Quantity4 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps1000.0 ac first location 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps1000.0 ac second location 
- 
                                    Circuit Protection Typeovercurrent all locations 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    