7235-8-7
Circuit Breakers
CIRCUIT BREAKER
7235-8-7
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Mounting Surface To Terminal End Distance2.328 inches nominal 
- 
                                    Fragility Factormoderately rugged 
- 
                                    Reset Methodmanual 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Terminal Type And Quantity2 screw 
- 
                                    Maximum Continuous Load Current Rating Per Pole7.0 amperes ac single location 
- 
                                    Circuit Protection Typeovercurrent single location 
- 
                                    Trip Release Methodthermal single location 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current20.000 minimum at 200 pct single location and 100.000 maximum at 200 pct single location 
- 
                                    Inclosure Protection Type For Which Designeddusttight and explosion proof and shock resistant and sand resistant and vibration resistant and corrosion resistant 
- 
                                    Body Width1.375 inches nominal 
- 
                                    Pole Quantity1 
- 
                                    Trip Release Ambient Temp Rating25.0 deg celsius nominal single location 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Unthreaded Mounting Hole Diameter0.203 inches nominal 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps2000.0 ac single location 
- 
                                    Body Stylesingle pole type 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length3.125 inches nominal 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent138.0 single location 
- 
                                    Overall Length3.625 inches nominal 
- 
                                    Frequency In Hertz60.0 single location 
- 
                                    Center To Center Distance Between Terminals Parallel To Length1.316 inches nominal 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts120.0 ac single location 
- 
                                    Case Materialplastic 
- 
                                    Internal Trip Release Configurationseries trip single location 
- 
                                    Mounting Facility Type And Quantity2 unthreaded hole 
- 
                                    Trip Release Characteristictime delay single location 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    