0411-35
Circuit Breakers
CIRCUIT BREAKER
0411-35
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Fragility Factormoderately rugged 
- 
                                    Thread Series Designatorunc 
- 
                                    Reset Methodmanual 
- 
                                    Trip Release Methodmagnetic-hydraulic single location 
- 
                                    Frequency In Hertz60.0 single location 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts120.0 ac single location 
- 
                                    Terminal Type And Quantity1 compression and 1 tab w/screw 
- 
                                    Center To Center Distance Between Terminals Parallel To Length4.370 inches minimum and 4.390 inches maximum 
- 
                                    Case Materialplastic 
- 
                                    Actuator Position Designationat pole one 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Body Height2.820 inches minimum and 2.840 inches maximum 
- 
                                    Body Width1.020 inches minimum and 1.040 inches maximum 
- 
                                    Mounting Facility Type And Quantity2 threaded hole 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Circuit Protection Typeovercurrent single location 
- 
                                    Body Length4.740 inches minimum and 4.760 inches maximum 
- 
                                    Pole Quantity1 
- 
                                    Manual Actuator Type And Quantity1 toggle 
- 
                                    Internal Trip Release Configurationseries trip single location 
- 
                                    Nominal Thread Size0.138 inches 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps5000.0 ac single location 
- 
                                    Inclosure Protection Type For Which Designeddustproof and fungus proof 
- 
                                    Trip Release Characteristictime delay single location 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 single location 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Arc Quenching Methodmagnetic blowout 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length2.740 inches minimum and 2.760 inches maximum 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current1.500 minimum at 200 pct single location and 60.000 maximum at 200 pct single location 
- 
                                    Body Stylesingle pole type 
- 
                                    Maximum Continuous Load Current Rating Per Pole35.0 amperes ac single location 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    