Technical Characteristics
- 
                                    Body Width1.250 inches nominal 
- 
                                    Mounting Facility Type And Quantity2 unthreaded hole 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts30.0 dc 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps600.0 dc 
- 
                                    Circuit Protection Typeovercurrent 
- 
                                    Overall Length2.000 inches nominal 
- 
                                    Case Materialplastic 
- 
                                    Center To Center Distance Between Terminals Parallel To Length0.781 inches nominal 
- 
                                    Unthreaded Mounting Hole Diameter0.190 inches nominal 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length1.574 inches nominal 
- 
                                    Mounting Surface To Terminal End Distance1.345 inches nominal 
- 
                                    Pole Quantity1 
- 
                                    Maximum Continuous Load Current Rating Per Pole60.0 amperes dc 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Manual Actuator Type And Quantity1 push button 
- 
                                    Actuator Functionreset 
- 
                                    Internal Trip Release Configurationseries trip 
- 
                                    Trip Release Ambient Temp Rating77.0 deg fahrenheit nominal 
- 
                                    Terminal Type And Quantity2 tab w/screw 
- 
                                    Trip Release Methodthermal 
- 
                                    Trip Release Characteristictime delay 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent138.0 
- 
                                    Reset Methodmanual 
- 
                                    Actuator Position Designationat pole one 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current5.500 minimum at 200 pct and 50.000 maximum at 200 pct 
- 
                                    Inclosure Protection Type For Which Designedvibration resistant and shock resistant 
- 
                                    Unpackaged Unit Weight1.750 ounces 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    