CF3-G3-U-90-9
Circuit Breakers
CIRCUIT BREAKER
CF3-G3-U-90-9
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Body Length5.844 inches nominal 
- 
                                    Center To Center Distance Between Terminals Parallel To Width1.032 inches nominal 
- 
                                    Fragility Factormoderately rugged 
- 
                                    Pole Quantity3 
- 
                                    Arc Quenching Methodmagnetic blowout 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts240.0 ac 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps5000.0 ac 
- 
                                    Trip Release Methodmagnetic-hydraulic 
- 
                                    Trip Release Characteristictime delay 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 
- 
                                    Reset Methodmanual 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Actuator Position Designationat each pole 
- 
                                    Inclosure Protection Type For Which Designedfungus resistant and moisture resistant 
- 
                                    Unpackaged Unit Weight2.000 pounds 
- 
                                    Thread Series Designatorunc 
- 
                                    Terminal Type And Quantity6 screw 
- 
                                    Mounting Slot Width0.164 inches nominal 
- 
                                    Body Width3.069 inches nominal 
- 
                                    Case Materialplastic 
- 
                                    Center To Center Distance Between Terminals Parallel To Length3.564 inches nominal 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length2.750 inches nominal 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Width1.032 inches nominal 
- 
                                    Boss Height0.218 inches nominal 
- 
                                    Mounting Surface To Terminal End Distance2.609 inches nominal 
- 
                                    Mounting Facility Type And Quantity6 threaded hole and 6 slot 
- 
                                    Special Handling Featuremagnetic 
- 
                                    Maximum Continuous Load Current Rating Per Pole90.0 amperes ac 
- 
                                    Circuit Protection Typeovercurrent 
- 
                                    Manual Actuator Type And Quantity3 toggle 
- 
                                    Actuator Functiontrip-reset 
- 
                                    External Actuator Linkage Arrangementone,two,and three linked 
- 
                                    Internal Trip Release Configurationseries trip 
- 
                                    Nominal Thread Size0.138 inches 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current20.000 minimum at 200 pct and 125.000 maximum at 200 pct 
- 
                                    Frequency In Hertz60.0 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    