UPG1-1-6-1-502-01
Circuit Breakers
CIRCUIT BREAKER
UPG1-1-6-1-502-01
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Frequency In Hertz60.0 single location 
- 
                                    Inclosure Protection Type For Which Designedmoisture resistant and salt spray proof and vibrationproof and ice resistant 
- 
                                    Ultimate Trip Time Per Pole In Seconds6.003 minimum single location and 0.040 maximum single location 
- 
                                    Case Materialplastic 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts277.0 ac single location 
- 
                                    Mounting Facility Type And Quantity2 threaded hole 
- 
                                    Maximum Continuous Load Current Rating Per Pole5.0 amperes ac single location 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Mounting Surface To Terminal End Distance2.000 inches maximum 
- 
                                    Circuit Protection Typeovercurrent single location 
- 
                                    Pole Quantity1 
- 
                                    Manual Actuator Type And Quantity1 toggle 
- 
                                    Internal Trip Release Configurationseries trip single location 
- 
                                    Nominal Thread Size0.138 inches 
- 
                                    Trip Release Characteristictime delay single location 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent1000.0 single location 
- 
                                    Terminal Type And Quantity2 tab, solder lug 
- 
                                    Center To Center Distance Between Terminals Parallel To Length1.530 inches nominal 
- 
                                    Body Stylesingle pole type 
- 
                                    Trip Release Methodmagnetic-hydraulic single location 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current12.000 maximum at 125 pct single location and 4.000 maximum at 150 pct single location and 0.130 maximum at 600 pct single location and 0.008 minimum at 600 pct single location and 0.220 maximum at 400 pct single location and 0.003 minimum at 800 pct 
- 
                                    ~1single location and 1.300 maximum at 200 pct sing 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length1.660 inches nominal 
- 
                                    Thread Series Designatorunc 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps1000.0 ac single location 
- 
                                    Reset Methodmanual 
- 
                                    Special Featureshandle color with on-off markings black with white markings 
- 
                                    Actuator Position Designationat pole one 
- 
                                    Body Width0.750 inches nominal 
- 
                                    Body Length2.000 inches nominal 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    