Technical Characteristics
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current0.009 minimum at 200 pct single location and 0.030 maximum at 200 pct single location 
- 
                                    Thread Pitch Diameters+0.1177/+0.1214 inches 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length2.035 inches minimum and 2.085 inches maximum 
- 
                                    Case Materialplastic 
- 
                                    Terminal Type And Quantity2 threaded stud 
- 
                                    Fragility Factormoderately rugged 
- 
                                    Trip Release Methodmagnetic single location 
- 
                                    Body Length2.465 inches minimum and 2.515 inches maximum 
- 
                                    Special Handling Featuremagnetic 
- 
                                    Boss Height0.110 inches minimum and 0.170 inches maximum 
- 
                                    Thread Series Designatorunc 
- 
                                    Reset Methodmanual 
- 
                                    Body Width0.723 inches minimum and 0.765 inches maximum 
- 
                                    Actuator Position Designationat pole one 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Maximum Continuous Load Current Rating Per Pole15.0 amperes dc single location 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Mounting Facility Type And Quantity2 threaded hole 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Circuit Protection Typeovercurrent single location 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps2000.0 dc single location 
- 
                                    Unpackaged Unit Weight0.250 pounds 
- 
                                    Pole Quantity1 
- 
                                    Manual Actuator Type And Quantity1 toggle 
- 
                                    Internal Trip Release Configurationseries trip single location 
- 
                                    Nominal Thread Size0.138 inches 
- 
                                    Trip Release Characteristictime delay single location 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent115.0 single location 
- 
                                    Mounting Surface To Terminal End Distance2.578 inches minimum and 2.640 inches maximum 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts50.0 dc single location 
- 
                                    Inclosure Protection Type For Which Designedgeneral purpose 
- 
                                    Center To Center Distance Between Terminals Parallel To Length1.909 inches minimum and 1.967 inches maximum 
- 
                                    Body Stylesingle pole type 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    