70-255-1MG6CURVE5
Circuit Breakers
CIRCUIT BREAKER
70-255-1MG6CURVE5
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Actuator Position Designationat pole one 
- 
                                    Auxiliary Switch Function And Quantity1 control 
- 
                                    Switch Location And Position Designationexternal at pole one 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current0.110 minimum at 200 pct and 0.180 maximum at 200 pct 
- 
                                    Switch Terminal Typesolder stud 
- 
                                    Test Data Document18876-11077014 drawing 
- 
                                    Terminal Type And Quantity2 threaded stud 
- 
                                    Body Stylesingle pole type 
- 
                                    Body Length2.530 inches nominal 
- 
                                    Body Width0.760 inches nominal 
- 
                                    Case Materialplastic 
- 
                                    Center To Center Distance Between Terminals Parallel To Length1.940 inches nominal 
- 
                                    Mounting Facility Type And Quantity2 threaded hole 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Maximum Continuous Load Current Rating Per Pole10.0 amperes dc 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts60.0 dc 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps2000.0 dc 
- 
                                    Circuit Protection Typeovercurrent 
- 
                                    Internal Trip Release Configurationseries trip 
- 
                                    Nominal Thread Size0.138 inches 
- 
                                    Inclosure Protection Type For Which Designedfungus resistant and moisture resistant 
- 
                                    Switch Current Rating And Type In Amps2.5 ac and 1.0 dc 
- 
                                    Switch Voltage Rating And Type In Volts250.0 ac and 50.0 dc 
- 
                                    Thread Series Designatorunc 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length2.060 inches nominal 
- 
                                    Switch Contact Arrangementsingle pole,double throw 
- 
                                    Fragility Factormoderately rugged 
- 
                                    Boss Height0.140 inches nominal 
- 
                                    Mounting Surface To Terminal End Distance2.900 inches nominal 
- 
                                    Pole Quantity1 
- 
                                    Trip Release Methodmagnetic-hydraulic 
- 
                                    Trip Release Characteristictime delay 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 
- 
                                    Reset Methodmanual 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Manual Actuator Type And Quantity1 toggle 
- 
                                    Actuator Functiontrip-reset 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    