50-110-25MG3
Circuit Breakers
CIRCUIT BREAKER
50-110-25MG3
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Fragility Factor
moderately rugged
-
Thread Series Designator
unc
-
Reset Method
manual
-
Actuator Position Designation
at pole one
-
Mounting Surface To Terminal End Distance
3.239 inches nominal
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Center To Center Distance Between Terminals Parallel To Length
3.053 inches minimum and 3.073 inches maximum
-
Mounting Facility Type And Quantity
2 threaded hole
-
Maximum Continuous Load Current Rating Per Pole
150.0 amperes dc single location
-
Thread Quantity Per Inch
32
-
Circuit Protection Type
overcurrent single location
-
Pole Quantity
1
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 dc single location
-
Manual Actuator Type And Quantity
1 toggle
-
Internal Trip Release Configuration
series trip single location
-
Nominal Thread Size
0.138 inches
-
Body Length
3.709 inches minimum and 3.729 inches maximum
-
Inclosure Protection Type For Which Designed
dustproof and fungus proof
-
Boss Height
0.146 inches minimum and 0.166 inches maximum
-
Case Material
plastic
-
Terminal Type And Quantity
2 threaded stud
-
Trip Release Characteristic
time delay single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.740 inches minimum and 2.760 inches maximum
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc single location
-
Body Style
single pole type
-
Trip Release Method
magnetic-hydraulic single location
-
Body Width
0.980 inches minimum and 1.000 inches maximum
-
Trip Delay Time In Seconds Per Rated Continuous Current
30.000 minimum at 200 pct single location and 100.000 maximum at 200 pct single location
Related Parts by Category
Related Parts by Manufacturer


AS6081 Methods