Technical Characteristics
- 
                                    Thread Series Designatorunef 
- 
                                    Unpackaged Unit Weight5.100 ounces 
- 
                                    Inclosure Protection Type For Which Designedhermetically sealed 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current0.050 minimum at 200 pct and 0.950 maximum at 200 pct 
- 
                                    Internal Trip Release Configurationseries trip 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Trip Release Methodmagnetic 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts50.0 dc 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Mounting Facility Type And Quantity1 threaded bushing w/panel seal 
- 
                                    Fragility Factormoderately rugged 
- 
                                    Center To Center Distance Between Terminals Parallel To Length0.870 inches minimum and 0.880 inches maximum 
- 
                                    Case Materialmetal 
- 
                                    Body Width0.567 inches minimum and 0.629 inches maximum 
- 
                                    Body Length1.448 inches minimum and 1.510 inches maximum 
- 
                                    Body Stylesingle pole type 
- 
                                    Terminal Type And Quantity2 wire hook 
- 
                                    Nominal Thread Size0.375 inches 
- 
                                    Actuator Position Designationat pole one 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Manual Actuator Type And Quantity1 toggle 
- 
                                    Reset Methodmanual 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 
- 
                                    Trip Release Characteristictime delay 
- 
                                    Circuit Protection Typeovercurrent 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps500.0 dc 
- 
                                    Maximum Continuous Load Current Rating Per Pole250.0 milliamperes dc 
- 
                                    Arc Quenching Methodmagnetic blowout 
- 
                                    Pole Quantity1 
- 
                                    Mounting Surface To Terminal End Distance1.524 inches minimum and 1.586 inches maximum 
- 
                                    Bushing Length0.360 inches minimum and 0.380 inches maximum 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    