390954
Circuit Breakers
CIRCUIT BREAKER
390954
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
900.0 ac single location and 900.0 dc single location
-
Terminal Type And Quantity
2 screw
-
Circuit Protection Type
overcurrent single location
-
Trip Release Method
thermal single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
-
Trip Release Characteristic
time delay single location
-
Mounting Facility Type And Quantity
2 unthreaded hole
-
Nondefinitive Spec/Std Data
iii type and b class
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac single location and 5.0 amperes dc single location
-
Pole Quantity
1
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
-
Overall Width
1.188 inches nominal
-
Operating Voltage Type And Rating Per Pole In Volts
15.0 ac single location and 30.0 dc single location
-
Case Material
plastic
-
Reset Method
automatic
-
Overall Length
2.000 inches nominal
-
Overall Height
1.250 inches nominal
-
Unthreaded Mounting Hole Diameter
0.188 inches nominal
-
Trip Delay Time In Seconds Per Rated Continuous Current
3600.000 nominal at 125 pct single location and 30.000 nominal at 200 pct single location
Related Parts by Category
Related Parts by Manufacturer


AS6081 Methods