AP-1-1-41-251
Circuit Breakers
CIRCUIT BREAKER
AP-1-1-41-251
Sensata Technologies Maryland Inc
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Bushing Length0.380 inches maximum 
- 
                                    Fragility Factormoderately rugged 
- 
                                    Trip Release Methodmagnetic single location 
- 
                                    Terminal Type And Quantity2 wire hook 
- 
                                    Special Handling Featuremagnetic 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps1000.0 ac single location 
- 
                                    Reset Methodmanual 
- 
                                    Mounting Facility Type And Quantity1 threaded bushing w/panel seal 
- 
                                    Actuator Position Designationat pole one 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Nominal Thread Size0.375 inches 
- 
                                    Maximum Continuous Load Current Rating Per Pole250.0 milliamperes ac single location 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Circuit Protection Typeovercurrent single location 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts110.0 ac single location 
- 
                                    Pole Quantity1 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current0.150 minimum at 200 pct single location and 0.600 maximum at 200 pct single location 
- 
                                    Case Materialmetal 
- 
                                    Manual Actuator Type And Quantity1 toggle 
- 
                                    Internal Trip Release Configurationseries trip single location 
- 
                                    Body Length1.500 inches maximum 
- 
                                    Trip Release Characteristictime delay single location 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Arc Quenching Methodmagnetic blowout 
- 
                                    Frequency In Hertz400.0 single location 
- 
                                    Body Stylesingle pole type 
- 
                                    Body Width0.625 inches maximum 
- 
                                    Mounting Surface To Terminal End Distance1.605 inches maximum 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent150.0 single location 
- 
                                    Thread Series Designatorunef 
- 
                                    Center To Center Distance Between Terminals Parallel To Length0.844 inches minimum and 0.906 inches maximum 
- 
                                    Inclosure Protection Type For Which Designedhermetically sealed and shock resistant and vibration resistant 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    