Technical Characteristics
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Trip Release Characteristictime delay all locations 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Body Length2.500 inches maximum 
- 
                                    Center To Center Distance Between Terminals Parallel To Length1.620 inches minimum 
- 
                                    Internal Trip Release Configurationseries trip all locations 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps1000.0 ac all locations 
- 
                                    Mounting Surface To Terminal End Distance2.465 inches nominal 
- 
                                    Mounting Facility Type And Quantity4 threaded hole 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Boss Height0.155 inches maximum 
- 
                                    Trip Release Methodmagnetic all locations 
- 
                                    Body Stylemultipole-multiple actuator type 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 all locations 
- 
                                    Maximum Continuous Load Current Rating Per Pole10.0 amperes ac all locations 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current0.800 minimum at 300 pct all locations and 4.500 maximum at 300 pct all locations 
- 
                                    Nominal Thread Size0.138 inches 
- 
                                    Frequency In Hertz60.0 all locations 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Width0.735 inches minimum and 0.765 inches maximum 
- 
                                    Circuit Protection Typeovercurrent all locations 
- 
                                    Center To Center Distance Between Terminals Parallel To Width0.735 inches minimum and 0.765 inches maximum 
- 
                                    Pole Quantity2 
- 
                                    Thread Series Designatorunc 
- 
                                    Actuator Position Designationat each pole 
- 
                                    Reset Methodmanual 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length2.063 inches nominal 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts208.0 ac all locations 
- 
                                    Special Handling Featuremagnetic 
- 
                                    Fragility Factormoderately rugged 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Arc Quenching Methodmagnetic blowout 
- 
                                    Manual Actuator Type And Quantity2 toggle 
- 
                                    Body Width1.515 inches maximum 
- 
                                    Inclosure Protection Type For Which Designedvibrationproof and moisture resistant and corrosion resistant and shockproof and fungus resistant 
- 
                                    Unpackaged Unit Weight7.400 ounces 
- 
                                    Terminal Type And Quantity4 threaded stud 
- 
                                    External Actuator Linkage Arrangementone and two linked 
- 
                                    Case Materialplastic 