368D451G03
Circuit Breakers
CIRCUIT BREAKER
368D451G03
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Body Height4.812 inches nominal 
- 
                                    Center To Center Distance Between Terminals Parallel To Length11.186 inches nominal 
- 
                                    Center To Center Distance Between Terminals Parallel To Width1.375 inches nominal 
- 
                                    Unthreaded Mounting Hole Diameter0.281 inches nominal 
- 
                                    Boss Height0.250 inches nominal 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts600.0 ac and 250.0 dc 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps15000.0 ac and 10000.0 dc 
- 
                                    Circuit Protection Typeovercurrent 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 
- 
                                    Reset Methodmanual 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Manual Actuator Type And Quantity1 toggle 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Frequency In Hertz400.0 
- 
                                    Terminal Type And Quantity4 compression 
- 
                                    Maximum Continuous Load Current Rating Per Pole30.0 amperes ac and 30.0 amperes dc 
- 
                                    Trip Release Methodthermal-magnetic 
- 
                                    Trip Release Characteristicinstantaneouss and time delay 
- 
                                    Actuator Position Designationbetween pole one and two 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current27.000 minimum at 200 pct and 65.000 maximum at 200 pct 
- 
                                    Inclosure Protection Type For Which Designedfungus resistant 
- 
                                    Trip Release Ambient Temp Rating40.0 deg celsius nominal 
- 
                                    Body Length11.812 inches nominal 
- 
                                    Body Width4.125 inches nominal 
- 
                                    Case Materialplastic 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length8.094 inches nominal 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Width1.375 inches nominal 
- 
                                    Pole Quantity2 
- 
                                    Mounting Facility Type And Quantity4 unthreaded hole 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    