7MC3-5-12
Circuit Breakers
CIRCUIT BREAKER
7MC3-5-12
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Fragility Factormoderately rugged 
- 
                                    Trip Release Methodmagnetic single location 
- 
                                    Switch Terminal Typetab, solder lug 
- 
                                    Bushing Length0.250 inches nominal 
- 
                                    Maximum Continuous Load Current Rating Per Pole12.0 amperes dc single location 
- 
                                    Reset Methodmanual 
- 
                                    Actuator Position Designationat pole one 
- 
                                    Center To Center Distance Between Terminals Parallel To Length1.341 inches nominal 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Terminal Type And Quantity2 screw 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps1000.0 dc single location 
- 
                                    Circuit Protection Typeovercurrent single location 
- 
                                    Mounting Facility Type And Quantity1 threaded bushing 
- 
                                    Manual Actuator Type And Quantity1 push-pull 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent135.0 single location 
- 
                                    Switch Contact Arrangementsingle pole, double throw 
- 
                                    Pole Quantity1 
- 
                                    Internal Trip Release Configurationseries trip single location 
- 
                                    Body Width0.656 inches nominal 
- 
                                    Trip Release Characteristictime delay single location 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Inclosure Protection Type For Which Designedshockproof and vibrationproof 
- 
                                    Switch Voltage Rating And Type In Volts28.0 dc 
- 
                                    Switch Current Rating And Type In Amps7.0 dc 
- 
                                    Body Stylesingle pole type 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current2.000 minimum at 200 pct single location and 4.000 maximum at 200 pct single location 
- 
                                    Unpackaged Unit Weight0.125 pounds 
- 
                                    Auxiliary Switch Function And Quantity1 alarm 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts32.0 dc single location 
- 
                                    Mounting Surface To Terminal End Distance1.669 inches nominal 
- 
                                    Nominal Thread Size0.469 inches 
- 
                                    Body Length1.781 inches nominal 
- 
                                    Switch Location And Position Designationinternal at pole one 
- 
                                    Thread Series Designatoruns 
- 
                                    Case Materialplastic 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    