Technical Characteristics
- 
                                    Center To Center Distance Between Terminals Parallel To Length0.875 inches nominal 
- 
                                    Mounting Facility Type And Quantity1 threaded bushing 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Maximum Continuous Load Current Rating Per Pole2.0 amperes ac single location 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts250.0 ac single location 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps300.0 ac single location 
- 
                                    Trip Release Characteristictime delay single location 
- 
                                    Ultimate Trip Time Per Pole In Seconds8.000 minimum and 15.500 maximum single location 
- 
                                    Internal Trip Release Configurationseries trip single location 
- 
                                    Nominal Thread Size0.375 inches 
- 
                                    Thread Series Designatorunef 
- 
                                    Frequency In Hertz400.0 
- 
                                    Test Data Document18876-11151832 drawing 
- 
                                    Terminal Type And Quantity2 wire hook 
- 
                                    Body Length1.479 inches nominal 
- 
                                    Case Materialmetal 
- 
                                    Body Style2a single pole type 
- 
                                    Bushing Length0.375 inches nominal 
- 
                                    Body Width0.598 inches nominal 
- 
                                    Mounting Surface To Terminal End Distance1.555 inches nominal 
- 
                                    Pole Quantity1 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Circuit Protection Typeovercurrent single location 
- 
                                    Trip Release Methodmagnetic-hydraulic single location 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 
- 
                                    Reset Methodmanual 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Manual Actuator Type And Quantity1 toggle 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Actuator Position Designationat pole one 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current1.000 minimum at 200 pct and 13.000 maximum at 200 pct single location 
- 
                                    Inclosure Protection Type For Which Designedfungus resistant and hermetically sealed 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    