Technical Characteristics
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent150.0 
- 
                                    Manual Actuator Type And Quantity4 toggle 
- 
                                    Internal Trip Release Configurationseries trip . 
- 
                                    Nominal Thread Size0.138 inches 
- 
                                    Frequency In Hertz400.0 
- 
                                    Thread Series Designatorunc 
- 
                                    Terminal Type And Quantity8 threaded stud 
- 
                                    Body Length2.500 inches nominal 
- 
                                    Body Width3.000 inches nominal 
- 
                                    Center To Center Distance Between Terminals Parallel To Length1.938 inches nominal 
- 
                                    Center To Center Distance Between Terminals Parallel To Width0.750 inches nominal 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length2.062 inches nominal 
- 
                                    Fragility Factormoderately rugged 
- 
                                    Boss Height0.140 inches nominal 
- 
                                    Mounting Surface To Terminal End Distance2.611 inches nominal 
- 
                                    Pole Quantity4 
- 
                                    Arc Quenching Methodmagnetic blowout 
- 
                                    Trip Release Methodmagnetic-hydraulic . 
- 
                                    Reset Methodmanual 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Actuator Position Designationat each pole 
- 
                                    External Actuator Linkage Arrangementone, two, three, and four linked 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current0.230 minimum at 200 pct and 10.000 maximum at 200 pct . 
- 
                                    Inclosure Protection Type For Which Designedexplosion resistant and fungus resistant and moisture resistant 
- 
                                    Unpackaged Unit Weight2.700 pounds 
- 
                                    Body Stylecaaql 8c 
- 
                                    Case Materialplastic 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Width0.750 inches nominal 
- 
                                    Mounting Facility Type And Quantity8 threaded hole 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Maximum Continuous Load Current Rating Per Pole1.0 amperes ac . 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts250.0 ac . 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps1000.0 ac . 
- 
                                    Circuit Protection Typeovercurrent . 
- 
                                    Trip Release Characteristictime delay . 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    