210-507-5
Circuit Breakers
CIRCUIT BREAKER
210-507-5
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Body Width2.250 inches maximum 
- 
                                    Fragility Factormoderately rugged 
- 
                                    Pole Quantity3 
- 
                                    Case Materialplastic 
- 
                                    Trip Release Methodthermal all locations 
- 
                                    Unpackaged Unit Weight0.650 pounds 
- 
                                    Circuit Protection Typeovercurrent all locations 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Width0.720 inches minimum and 0.780 inches maximum 
- 
                                    Thread Series Designatorunc 
- 
                                    Reset Methodmanual 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Trip Release Characteristictime delay all locations 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent138.0 all locations 
- 
                                    Bushing Length0.235 inches minimum and 0.250 inches maximum 
- 
                                    Inclosure Protection Type For Which Designedsand resistant and humidity proof and dustproof and explosion proof and corrosion resistant and fungus resistant 
- 
                                    Frequency In Hertz400.0 all locations 
- 
                                    Terminal Type And Quantity6 tab w/screw 
- 
                                    Internal Trip Release Configurationseries trip all locations 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Body Height2.440 inches minimum and 2.500 inches maximum 
- 
                                    Manual Actuator Type And Quantity1 push-pull 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps4200.0 ac all locations 
- 
                                    Actuator Position Designationat pole two 
- 
                                    Center To Center Distance Between Terminals Parallel To Length1.160 inches minimum and 1.220 inches maximum 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length1.800 inches minimum and 1.820 inches maximum 
- 
                                    Mounting Facility Type And Quantity6 threaded hole 
- 
                                    Body Stylemultipole-single actuator type 
- 
                                    Trip Release Ambient Temp Rating25.0 deg celsius nominal all locations 
- 
                                    Maximum Continuous Load Current Rating Per Pole5.0 amperes ac all locations 
- 
                                    Body Length2.189 inches maximum 
- 
                                    Nominal Thread Size0.138 inches 
- 
                                    Center To Center Distance Between Terminals Parallel To Width0.720 inches minimum and 0.780 inches maximum 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current12.000 minimum at 200 pct all locations and 38.000 maximum at 200 pct all locations 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts205.0 ac all locations 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    