Technical Characteristics
- 
                                    Nominal Thread Size0.138 inches 
- 
                                    Frequency In Hertz60.0 all locations 
- 
                                    Body Length5.768 inches minimum and 5.832 inches maximum 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Arc Quenching Methodmagnetic blowout 
- 
                                    Body Height2.577 inches minimum and 2.641 inches maximum 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Internal Trip Release Configurationseries trip all locations 
- 
                                    Trip Release Characteristicinstantaneous all locations and time delay all locations 
- 
                                    Mounting Facility Type And Quantity4 threaded hole 
- 
                                    Boss Height0.187 inches minimum and 0.251 inches maximum 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Trip Release Methodmagnetic all locations 
- 
                                    Body Stylemultipole-multiple actuator type 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 all locations 
- 
                                    Body Width2.020 inches minimum and 2.084 inches maximum 
- 
                                    Terminal Type And Quantity4 compression 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps10000.0 ac all locations 
- 
                                    Fragility Factormoderately rugged 
- 
                                    Circuit Protection Typeovercurrent all locations 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current39.000 minimum at 200 pct all locations and 100.000 maximum at 200 pct all locations 
- 
                                    Inclosure Protection Type For Which Designeddustproof 
- 
                                    Pole Quantity2 
- 
                                    Thread Series Designatorunc 
- 
                                    Actuator Position Designationat each pole 
- 
                                    Reset Methodmanual 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Maximum Continuous Load Current Rating Per Pole35.0 amperes ac second location 
- 
                                    Trip Release Duty Cyclecontinuous all locations 
- 
                                    Manual Actuator Type And Quantity2 toggle 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts220.0 ac first location 
- 
                                    Center To Center Distance Between Terminals Parallel To Width0.994 inches minimum and 1.058 inches maximum 
- 
                                    Maximum Continuous Load Current Rating Per Pole17.5 amperes ac first location 
- 
                                    External Actuator Linkage Arrangementone and two linked 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts440.0 ac second location 
- 
                                    Case Materialplastic 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    