B4524-3975-6
Circuit Breakers
CIRCUIT BREAKER
B4524-3975-6
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Thread Quantity Per Inch32 
- 
                                    Circuit Protection Typeovercurrent single location 
- 
                                    Unpackaged Unit Weight5.000 ounces 
- 
                                    Switch Contact Arrangementsingle pole, double throw 
- 
                                    Inclosure Protection Type For Which Designedfungus resistant and moisture resistant 
- 
                                    Pole Quantity1 
- 
                                    Boss Height0.125 inches minimum and 0.135 inches maximum 
- 
                                    Body Width0.780 inches maximum 
- 
                                    Manual Actuator Type And Quantity1 toggle 
- 
                                    Internal Trip Release Configurationseries trip single location 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts230.0 ac single location 
- 
                                    Auxiliary Switch Function And Quantity1 alarm 
- 
                                    Terminal Type And Quantity2 tab w/screw 
- 
                                    Frequency In Hertz60.0 single location 
- 
                                    Trip Release Methodmagnetic-hydraulic single location 
- 
                                    Center To Center Distance Between Terminals Parallel To Length1.970 inches maximum 
- 
                                    Body Stylesingle pole type 
- 
                                    Arc Quenching Methodmagnetic blowout 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current1.500 minimum at 200 pct single location and 6.000 maximum at 200 pct single location 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 single location 
- 
                                    Trip Release Characteristictime delay single location 
- 
                                    Nominal Thread Size0.138 inches 
- 
                                    Mounting Surface To Terminal End Distance2.430 inches maximum 
- 
                                    Switch Voltage Rating And Type In Volts125.0 ac 
- 
                                    Switch Location And Position Designationinternal at pole one 
- 
                                    Case Materialplastic 
- 
                                    Maximum Continuous Load Current Rating Per Pole22.5 amperes ac single location 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length2.050 inches minimum and 2.070 inches maximum 
- 
                                    Mounting Facility Type And Quantity2 threaded hole 
- 
                                    Body Length2.540 inches maximum 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Actuator Position Designationat pole one 
- 
                                    Reset Methodmanual 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps1000.0 ac single location 
- 
                                    Switch Current Rating And Type In Amps5.0 ac 
- 
                                    Thread Series Designatorunc 
- 
                                    Special Handling Featuremagnetic 
- 
                                    Switch Terminal Typetab, solder lug 
- 
                                    Fragility Factormoderately rugged 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    